MEA Amplifier for Upright Microscopes Manual

Seite 2

MEA Amplifier for Upright Microscopes - Manual 6 3.2 Setting Up and Connecting the MEA Amplifier Warning: Spilled liquid can damage or even complete

Seite 3 - Table of Contents

7 4 First Tests and Tutorial 4.1 First Functional Tests Each MEA amplifier has been thoroughly tested at the factory site before delivery. However,

Seite 4

MEA Amplifier for Upright Microscopes - Manual 8 The following screen shot shows a recording from a typical MEA amplifier with a test model probe and

Seite 5 - 1 Introduction

9 5 Operating the MEA Amplifier 5.1 Signal Amplification and Filters The standard MEA amplifier combines the probe interface with a band pass filter

Seite 6

MEA Amplifier for Upright Microscopes - Manual 10 If you use a MEA-System, the isolated power supply IPS10W that is integrated in the data acquisitio

Seite 7 - 2.2 Guarantee and Liability

Operating the MEA Amplifier 11 5.3 Mounting the MEA Probe and Grounding the Bath Warning: Do not use too much force. Otherwise you could damage the

Seite 8 - 2.3 Important Safety Advice

MEA Amplifier for Upright Microscopes - Manual 12 Grounding the bath You can ground the bath with a plain silver wire or with an Ag/AgCl pellet. Only

Seite 9

Operating the MEA Amplifier 13 5.4 Stimulation Recommended stimulus protocols for MEA electrodes MCS recommends to use biphasic pulses only, with nega

Seite 11 - 4 First Tests and Tutorial

15 6 Troubleshooting 6.1 About Troubleshooting The following hints are provided to solve special problems that have been reported by users. Most pro

Seite 12

Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted without the express wri

Seite 13

MEA Amplifier for Upright Microscopes - Manual 16 Contact pin is defective Possible causes: ? The contact pins are contaminated.  Clean the contac

Seite 14 - 5.2 Temperature Control

Troubleshooting 17 6.4 Artifacts on All Channels You see strange artifacts on all channels. This behavior can be caused by an insufficient supply pow

Seite 15

MEA Amplifier for Upright Microscopes - Manual 18 6.5 Liquid Spilled onto Amplifier Warning: Spilled liquid can damage or even completely destroy th

Seite 16

19 7 Appendix 7.1 Technical Specifications 7.1.1 Pin and MEA Layout The layout of standard MEA electrodes follows the scheme of a standard grid: The

Seite 17 - 5.5 Service and Maintenance

MEA Amplifier for Upright Microscopes - Manual 20 Assignment pin to electrode 68-Pin socket pin MEA electrode 68-Pin socket pin MEA electrode 3

Seite 18

Appendix 21 7.1.2 MEA1060-Up Operating temperature 10 °C to 50 °C Storage temperature 0 °C to 50 °C Dimensions (W x D x H) 165 mm x 165 mm x 14

Seite 19 - 6 Troubleshooting

MEA Amplifier for Upright Microscopes - Manual 22 Pin layout 7.1.4 Test Model Probe The provided test model probe simulates a MEA with a resistor o

Seite 20 - 6.3 Unsteady Baseline

Appendix 23 7.3 Ordering Information Product information is subject to change without notice. Please contact your local retailer for pricing and order

Seite 21

MEA Amplifier for Upright Microscopes - Manual 24 USB-MEA-System with blanking circuit for inverted microscopes USB-MEA240-Inv-4-BC-System board. The

Seite 22 - 6.6 Technical Support

Appendix 25 Accessories Product Product Number Description Adapter for MEAs with 8 special electrodes for stimulation MEA-STIM-Adapter For use with M

Seite 23 - 7 Appendix

iii Table of Contents Introduction 1 About this Manual 1 Important Information and Instructions 3 Operator's Obligations 3 Guarantee and Lia

Seite 24

MEA Amplifier for Upright Microscopes - Manual 26 Spare Parts Product Product Number Description Heating element with 8 mm bore hole HE-Inv-8 Heating

Seite 25 - 7.1.2 MEA1060-Up

Appendix 27 MEA-Systems Product Product Number Description MEA recording system for inverted microscopes, 60 electrode channels MEA60-Inv-System Comp

Seite 28

MEA Amplifier for Upright Microscopes - Manual 30

Seite 29

31 A Aliasing 9 B Band pass band...9 Bandwidth 9 C Change MEA 11 Configuration 13 Connecting 6 Contact Inf

Seite 32

1 1 Introduction 1.1 About this Manual This manual comprises all important information about the first installation of the hardware and software, a

Seite 34

3 2 Important Information and Instructions 2.1 Operator's Obligations The operator is obliged to allow only persons to work on the device, who

Seite 35

MEA Amplifier for Upright Microscopes - Manual 4 2.3 Important Safety Advice Warning: Make sure to read the following advice prior to install or to

Seite 36

5 3 First Use of the MEA Amplifier 3.1 Welcome to the MEA Amplifier Raw data from up to 60 electrodes of a microelectrode array (MEA) is amplified