Technical Specifications
Date of Print: 11.07.2005
STG1002 Stimulus generator
O
p
eratin
g
tem
p
erature 10 °C to 35 °C
Stora
g
e tem
p
erature 0 °C to 50 °C
Relative humidit
y
10 % to 85 %, non-condensin
g
Dimensions (W x D x H) 170 mm x 240 mm x 60 mm
Wei
g
ht 1.2 k
g
Fuse 1 A @ 100 to 230 V, slow blow
Su
pp
l
y
volta
g
e (external
p
ower su
pp
l
y
) 100-240 VAC @ 47 to 63 Hz
Resolution 13 bit
Time resolution 20
µ
s
Out
p
ut si
g
nals Freel
y
p
ro
g
rammable (rectan
g
ular, ram
p
, sinusoidal)
Out
p
ut rate 50 kHz
Volta
g
e out
p
uts
Number of analo
g
volta
g
e out
p
uts
2
Number of inverted analo
g
volta
g
e out
p
uts
2
Out
p
ut volta
g
e -8 V to +8 V
Out
p
ut volta
g
e resolution 2 m
V
Out
p
ut volta
g
e slo
p
e > 4 V/
µ
s
Rise time (10-90 %) 3 to 5
µ
s @ delta U = 1 V
Maximum out
p
ut current +/-20 mA
Time la
g
between S
y
nc Out and volta
g
e out
p
ut 12
µ
s +/-2 (@ am
p
litude > 200 mV)
Current out
p
ut
s
Number of analog current outputs 2
Number of inverted analog current outputs 2
Output current -0.8 mA to +0.8 mA
Output current resolution 200 nA
Output current slope 100 µA/µ
s (@ RL = 10 kilohms)
Rise time (10-90 %) 3 to 5 µs @ delta I = 0.4 mA & RL = 10 kilohms
Compliance voltage max. 150 V, guaranteed 120 V @ 0.8 mA (between -I and +I outputs)
Time lag between Sync Out and current output 15 µs +/-2 (@ amplitude > 100 µA & RL = 10 kilohms)
Timing on external trigger
Minimum time length of trigger input (TTL) 20 µs
Time lag between trigger input and stimulus output
120 +/- 10 µs
Time lag between trigger input and Sync Out 110 +/- 10 µs
Maximum trigger input frequency 50 Hz
Interface and connectors
Sync Out for synchronization with following devices Digital channel via coax cable
Trig In for synchronization with preceding devices Digital channel via coax cable
Interface (connection to computer) RS232 serial port
Download rate 56 Kbps
MC_Stimulus program
Operating system
Microsoft Windows ® Vista or XP; English and German versions